Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
1.
Opt Express ; 30(2): 2933-2948, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35209424

RESUMEN

Maintaining a high spatial resolution in photoacoustic microscopy (PAM) of deep tissues is difficult due to large aberration in an objective lens with high numerical aperture and photoacoustic wave attenuation. To address the issue, we integrate transmission-type adaptive optics (AO) in high-resolution PAM with a low-frequency ultrasound transducer (UT), which increases the photoacoustic wave detection efficiency. AO improves lateral resolution and depth discrimination in PAM, even for low-frequency ultrasound waves by focusing a beam spot in deep tissues. Using the proposed PAM, we increased the lateral resolution and depth discrimination for blood vessels in mouse ears.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Oído/irrigación sanguínea , Microscopía Acústica/instrumentación , Óptica y Fotónica , Técnicas Fotoacústicas/instrumentación , Transductores , Animales , Diseño de Equipo , Ratones
2.
Ultrasonics ; 118: 106580, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34555738

RESUMEN

Recently, a method for estimating three-dimensional acoustic impedance profiles in cultured cells and human dermal organs was proposed by interpreting the reflected ultrasonic signal based on a 1-D transmission line model for acoustic impedance microscopy (AIM). However, AIM has a disadvantage that reflected signals from cells overlap with that from a reference substrate. Additionally, the amplitudes of the reflected signals from the specimens are significantly weaker than that from the substrate. In this paper, we proposed a new method for separation of those signals based on a concept of clutter filter, which had been developed for a color Doppler method in medical ultrasonic imaging. The proposed filter using singular value decomposition (SVD) could separate original signals into desired signals such as those from the substrate and cells. Additionally, an effect from a tilt of the substrate was investigated in this study. Separability of the proposed filter was evaluated by two investigations. First one was to evaluate the separability by estimating a correlation coefficient between the filtered signal and signal reflected from a position only with the substrate. Second one was to compare a slope of the substrate estimated from the original signal with that estimated from the filtered signals from the substrate. The experimental results showed that the proposed filter could separate signals from the substrate, and the compensation of the tilt of the substrate could improve the performance of the proposed filter.


Asunto(s)
Astrocitos/ultraestructura , Células Cultivadas/ultraestructura , Microscopía Acústica/instrumentación , Animales , Diseño de Equipo , Ratas , Procesamiento de Señales Asistido por Computador
3.
Appl Opt ; 60(24): 7107-7112, 2021 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-34612995

RESUMEN

Acousto-optic (AO) imaging is an in-depth optical imaging technique of highly scattering media. One challenging end-application for this technique is to perform imaging of living biological tissues. Indeed, because it relies on coherent illumination, AO imaging is sensitive to speckle decorrelation occurring on the millisecond time scale. Camera-based detections are well suited for in vivo imaging provided their integration time is lower than those decorrelation time scales. We present Fourier transform acousto-optic imaging combined with off-axis holography, which relies on plane waves and long-duration pulses. We demonstrate, for the first time to the best of our knowledge, a two-dimensional imaging system fully compatible with in vivo imaging prerequisites. The method is validated experimentally by performing in-depth imaging inside a multiple scattering sample.


Asunto(s)
Análisis de Fourier , Holografía/métodos , Microscopía Acústica/instrumentación , Imagen Óptica/instrumentación , Acústica , Fantasmas de Imagen , Dispersión de Radiación
4.
Opt Lett ; 46(2): 372-375, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33449032

RESUMEN

Optical resolution photoacoustic microscopy (ORPAM) has demonstrated both high resolution and rich contrast imaging of optical chromophores in biologic tissues. To date, sensitivity remains a major challenge for ORPAM, which limits the capability of resolving biologic microvascular networks. In this study, we propose and evaluate a new ORPAM modality termed as optical resolution photoacoustic computed microscopy (ORPACM), through the combination of a two-dimensional laser-scanning system with a medical ultrasonographic platform. Apart from conventional ORPAMs, we record multiple photoacoustic (PA) signals using a 128-element ultrasonic transducer array for each pulse excitation. Then, we apply a reconstruction algorithm to recover one depth-resolved PA signal referred to as an A-line, which reveals more detailed information compared with conventional single-element transducer-based ORPAMs. In addition, we carried out both in vitro and in vivo experiments as well as quantitative analyses to show the advanced features of ORPACM.


Asunto(s)
Encéfalo/irrigación sanguínea , Microscopía Acústica/instrumentación , Microvasos/diagnóstico por imagen , Técnicas Fotoacústicas/instrumentación , Análisis Espectral , Algoritmos , Animales , Procesamiento de Imagen Asistido por Computador/métodos , Ratones , Ratones Endogámicos BALB C , Microscopía Acústica/métodos , Técnicas Fotoacústicas/métodos , Transductores
5.
Artículo en Inglés | MEDLINE | ID: mdl-32286968

RESUMEN

We report the development of an optically transparent high-frequency ultrasonic transducer using lithium niobate single-crystal and indium-tin-oxide electrodes with up to 90% optical transmission in the visible-to-near-infrared spectrum. The center frequency of the transducer was at 36.9 MHz with 33.9%, at -6 dB fractional bandwidth. The photoacoustic imaging capability of the fabricated transducer was also demonstrated by successfully imaging a resolution target and mouse-ear vasculatures in vivo, which were irradiated by a 532 nm pulse laser transmitted through the transducer.


Asunto(s)
Microscopía Acústica/instrumentación , Técnicas Fotoacústicas/instrumentación , Transductores , Animales , Oído/irrigación sanguínea , Oído/diagnóstico por imagen , Diseño de Equipo , Ratones , Fantasmas de Imagen
6.
Artif Organs ; 43(11): 1104-1110, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31197836

RESUMEN

Development of artificial tissues or organs is one of the actual tasks in regenerative medicine that requires observation and evaluation of intact volume microstructure of tissue engineering products at all stages of their formation, from native donor tissues and decellularized scaffolds to recipient cell migration in the matrix. Unfortunately in practice, methods of vital noninvasive imaging of volume microstructure in matrixes are absent. In this work, we propose a new approach based on high-frequency acoustic microscopy for noninvasive evaluation and visualization of volume microstructure in tissue engineering products. The results present the ultrasound characterization of native rat diaphragms and lungs and their decellularized scaffolds. Verification of the method for visualization of tissue formation in the matrix volume was described in the model samples of diaphragm scaffolds with stepwise collagenization. Results demonstrate acoustic microscopic sensitivity to cell content concentration, variation in local density, and orientation of protein fibers in the volume, micron air inclusions, and other inhomogeneities of matrixes.


Asunto(s)
Diafragma/ultraestructura , Matriz Extracelular/ultraestructura , Pulmón/ultraestructura , Microscopía Acústica/métodos , Andamios del Tejido , Animales , Diafragma/química , Diafragma/citología , Diseño de Equipo , Matriz Extracelular/química , Pulmón/química , Pulmón/citología , Masculino , Microscopía Acústica/instrumentación , Ratas , Ratas Wistar , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
7.
Sci Rep ; 8(1): 14378, 2018 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-30258115

RESUMEN

Atherosclerotic plaques constitute the primary cause of heart attack and stroke. However, we still lack a clear identification of the plaques. Here, we evaluate the feasibility of scanning acoustic microscopy (SAM) and time-resolved fluorescence spectroscopy (TRFS) in atherosclerotic plaque characterization. We perform dual-modality microscopic imaging of the human carotid atherosclerotic plaques. We first show that the acoustic impedance values are statistically higher in calcified regions compared with the collagen-rich areas. We then use CdTe/CdS quantum dots for imaging the atherosclerotic plaques by TRFS and show that fluorescence lifetime values of the quantum dots in collagen-rich areas are notably different from the ones in calcified areas. In summary, both modalities are successful in differentiating the calcified regions from the collagen-rich areas within the plaques indicating that these techniques are confirmatory and may be combined to characterize atherosclerotic plaques in the future.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Microscopía Acústica/instrumentación , Placa Aterosclerótica/diagnóstico por imagen , Espectrometría de Fluorescencia/instrumentación , Anciano , Anciano de 80 o más Años , Algoritmos , Compuestos de Cadmio/química , Diseño de Equipo , Femenino , Humanos , Masculino , Microscopía Acústica/métodos , Persona de Mediana Edad , Puntos Cuánticos/química , Compuestos de Selenio/química , Espectrometría de Fluorescencia/métodos , Telurio/química
8.
World J Gastroenterol ; 24(31): 3531-3537, 2018 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-30131659

RESUMEN

AIM: To image stomach wall blood vessels and tissue, layer-by-layer. METHODS: We built up the acoustic resolution photoacoustic microscopy (AR-PAM) system for imaging layered tissues, such as the stomach wall. A tunable dye laser system was coupled to a fiber bundle. The fibers of the bundle were placed in nine directions with an incident angle of 45° around a high-frequency ultrasound transducer attached to the acoustic lens. This structure formed a dark field on the tissue surface under the acoustic lens and the nine light beams from the fibers to be combined near the focal point of the acoustic lens. The sample piece was cut from a part of the porcine stomach into a petri dish. In order to realize photoacoustic depth imaging of tumor, we designed a tumor model based on indocyanine green (ICG) dye. The ICG solution (concentration of 129 µM/mL) was mixed into molten gel, and then a gel mixture of ICG (concentration of 12.9 µM/mL) was injected into the stomach submucosa. The injection quantity was controlled by 0.1 mL to make a small tumor model. RESULTS: An acoustic resolution photoacoustic microscopy based on fiber illumination was established and an axial resolution of 25 µm and a lateral resolution of 50 µm in its focal zone range of 500 µm has been accomplished. We tuned the laser wavelength to 600 nm. The photoacoustic probe was driven to do B-scan imaging in tissue thickness of 200 µm. The photoacoustic micro-image of mucosa and submucosa of the tissue have been obtained and compared with a pathological photograph of the tissue stained by hematoxylin-eosin staining. We have observed more detailed internal structure of the tissue. We also utilized this photoacoustic microscopy to image blood vessels inside the submucosa. High contrast imaging of the submucosa tumor model was obtained using ICG dye. CONCLUSION: This AR-PAM is able to image layer-by-layer construction and some blood vessels under mucosa in the stomach wall without any contrast agents.


Asunto(s)
Microscopía Acústica/métodos , Microvasos/diagnóstico por imagen , Neoplasias Gástricas/diagnóstico por imagen , Estómago/diagnóstico por imagen , Animales , Colorantes/química , Modelos Animales de Enfermedad , Diseño de Equipo , Humanos , Aumento de la Imagen/métodos , Verde de Indocianina/química , Láseres de Colorantes , Microscopía Acústica/instrumentación , Estómago/irrigación sanguínea , Sus scrofa
9.
Rev Sci Instrum ; 89(7): 073705, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30068110

RESUMEN

Grooved nerve guide conduits (NGCs) have been effective in the clinical treatment of peripheral nerve injury. They are generally fabricated from a micro-structured spinneret using a spinning process, which easily can cause a variety of pores and morphological deviation. The topography of internal grooves as well as the porosity can greatly influence the therapeutic effect. Traditional optical or scanning electron microscopy (SEM) methods can be used to image the grooves; however, these methods are destructive and require slicing NGCs to prepare specimens suitable for imaging. Moreover, lengthy experiments and large batches of NGCs are required to ensure reliable results from both in vitro experiments and clinical studies. In this paper, a non-destructive method for evaluating the grooves and porosity of NGCs is proposed using ultrasonic imaging combined with rotary scanning and an image analysis algorithm. Two ultrasonic methods were used: a 25-MHz point-focus ultrasonic transducer applied to observe axial cross sections of the conduits and a 100-MHz point-focus ultrasonic transducer to detect large pores caused by defects. Furthermore, a theoretical algorithm for detecting the local porosity of a conduit based on density is proposed. Herein, the proposed acoustic method and traditional optical methods are evaluated and compared. A parameter representing the specific surface area of the internal grooves is introduced and computed for both the optical and acoustic methods, and the relative errors of the computed parameter values for three different NGCs were 7.0%, 7.9%, and 15.3%. The detected location and shape of pores were consistent between the acoustic and optical methods, and greater porosity was observed in the middle of the conduit wall. In this paper, the results of the acoustic and optical methods are presented and the errors relating to the acoustic factors, device characteristics, and image processing method are further analyzed.


Asunto(s)
Regeneración Tisular Dirigida , Ensayo de Materiales/métodos , Microscopía Acústica/métodos , Regeneración Nerviosa , Andamios del Tejido , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Acústica/instrumentación , Imagen Óptica , Nervios Periféricos , Porosidad , Control de Calidad
10.
Opt Lett ; 43(5): 1119-1122, 2018 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29489793

RESUMEN

We present a miniature probe capable of both optical-resolution (OR) and acoustic-resolution (AR) photoacoustic microscopy. A gradient-index-lens fiber and a multimode fiber are used to deliver light for OR and AR illumination, respectively. The probe achieves lateral resolution of 3.1 µm for OR mode and 46-249 µm (at depth of 1.2-4.3 mm) for AR mode, respectively. The size of the probe attains 3.7 mm in diameter, which can be used for endoscopic applications. In vivo imaging of several different parts of a mouse demonstrates the excellent imaging ability of the probe.


Asunto(s)
Oído Externo/irrigación sanguínea , Ojo/irrigación sanguínea , Microscopía Acústica/instrumentación , Microvasos/diagnóstico por imagen , Técnicas Fotoacústicas/instrumentación , Animales , Diseño de Equipo , Aumento de la Imagen , Ratones , Miniaturización , Fantasmas de Imagen
11.
Opt Lett ; 43(4): 947-950, 2018 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-29444034

RESUMEN

Photoacoustic microscopy (PAM) with ultraviolet (UV) laser illumination has recently been demonstrated as a promising tool that provides fast, label-free, and multilayered histologic imaging of human breast tissue. Thus far, the axial resolution has been determined ultrasonically. To enable optically defined axial resolution, we exploit the Grüneisen relaxation (GR) effect. By imaging mouse brain slices, we show that GRUV-PAM reveals detailed information about three-dimensional cell nuclear distributions and internal structures, which are important diagnostic features for cancers. Due to the nonlinear effect, GRUV-PAM also provides better contrast in images of cell nuclei.


Asunto(s)
Núcleo Celular/metabolismo , Microscopía Acústica/métodos , Técnicas Fotoacústicas/métodos , Animales , Encéfalo/citología , Encéfalo/diagnóstico por imagen , Ratones , Microscopía Acústica/instrumentación , Técnicas Fotoacústicas/instrumentación
12.
Sci Rep ; 7(1): 17518, 2017 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-29235512

RESUMEN

We report a multimodal biomicroscopic system which offers high-frequency ultrasound B-mode, acoustic radiation force impulse (ARFI), and multispectral imaging for qualitative tumor characterization ex vivo. Examinations of resected tissues from diseased regions such as tumors are crucial procedures during surgical operations to treat cancer. Particularly, if tiny tumors remain at surgical sites after tumor resection, such tumors can result in unwanted outcomes, such as cancer recurrence or metastasis to other organs. To avoid this, accurate characterizations of tumors resected during surgery are necessary. To this end, we devised a multimodal biomicroscopic system including high-frequency ultrasound B-mode, ARFI, and multispectral imaging modalities to examine resected tumors with high levels of accuracy. This system was evaluated with tissue-mimicking phantoms with different mechanical properties. In addition, colorectal tumors excised from cancer patients were examined. The proposed system offers highly resolved anatomical, mechanical, chemical information pertaining to tumors, thus allowing the detection of tumor regions from the surface to deep inside tissues. These results therefore suggest that the multimodal biomicroscopic system has the potential to undertake qualitative characterizations of excised tumors ex vivo.


Asunto(s)
Microscopía Acústica/instrumentación , Imagen Multimodal/instrumentación , Neoplasias/diagnóstico por imagen , Fenómenos Biomecánicos , Diseño de Equipo , Humanos , Microscopía Acústica/métodos , Imagen Multimodal/métodos , Neoplasias/patología , Neoplasias/fisiopatología , Neoplasias/cirugía , Fantasmas de Imagen
13.
IEEE Trans Biomed Eng ; 64(3): 715-724, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27249824

RESUMEN

OBJECTIVE: This paper describes development of a novel 500-MHz scanning acoustic microscope (SAM) for assessing the mechanical properties of ocular tissues at fine resolution. The mechanical properties of some ocular tissues, such as lamina cribrosa (LC) in the optic nerve head, are believed to play a pivotal role in eye pathogenesis. METHODS: A novel etching technology was used to fabricate silicon-based lens for a 500-MHz transducer. The transducer was tested in a custom-designed scanning system on human eyes. Two-dimensional (2-D) maps of bulk modulus (K) and mass density (ρ) were derived using improved versions of current state-of-the-art signal processing approaches. RESULTS: The transducer employed a lens radius of 125 µm and had a center frequency of 479 MHz with a -6-dB bandwidth of 264 MHz and a lateral resolution of 4 µm. The LC, Bruch's membrane (BM) at the interface of the retina and choroid, and Bowman's layer (BL) at the interface of the corneal epithelium and stroma, were successfully imaged and resolved. Analysis of the 2-D parameter maps revealed average values of LC, BM, and BL with KLC = 2.81 ±0.17; GPa, KBM = 2.89 ±0.18; GPa, KBL = 2.6 ±0.09 ; GPa, ρ LC = 0.96 ±0.03 g/cm3; ρ BM = 0.97 ±0.04 g/cm3; ρ BL = 0.98 ±0.04 g/cm3. SIGNIFICANCE: This novel SAM was shown to be capable of measuring mechanical properties of soft biological tissues at microscopic resolution; it is currently the only system that allows simultaneous measurement of K, ρ, and attenuation in large lateral scales (field area >9 mm2) and at fine resolutions.


Asunto(s)
Aumento de la Imagen/instrumentación , Lentes , Microscopía Acústica/instrumentación , Oftalmoscopios , Retina/citología , Retina/diagnóstico por imagen , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Transductores
14.
Phys Med Biol ; 62(2): 501-516, 2017 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-28000617

RESUMEN

Macrophages are excellent imaging targets for detecting atherosclerotic plaques as they are involved in all the developmental stages of atherosclerosis. However, no imaging technique is currently capable of visualizing macrophages inside blood vessel walls. The current study develops an intravascular ultrasonic-photoacoustic (IVUP) imaging system combined with indocyanine green (ICG) as a contrast agent to provide morphological and compositional information about the targeted samples. Both tissue-mimicking vessel phantoms and atherosclerotic plaque-mimicking porcine arterial tissues are used to demonstrate the feasibility of mapping macrophages labeled with ICG by endoscopically applying the proposed hybrid technique. A delay pulse triggering technique is able to sequentially acquire photoacoustic (PA) and ultrasound (US) signals from a single scan without using any external devices. The acquired PA and US signals are used to reconstruct 2D cross-sectional and 3D volumetric images of the entire tissue with the ICG-loaded macrophages injected. Due to high imaging contrast and sensitivity, the IVUP imaging vividly reveals structural information and detects the spatial distribution of the ICG-labeled macrophages inside the samples. ICG-assisted IVUP imaging can be a feasible imaging modality for the endoscopic detection of atherosclerotic plaques.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Macrófagos/patología , Microscopía Acústica/instrumentación , Fantasmas de Imagen , Placa Aterosclerótica/diagnóstico , Ultrasonografía/instrumentación , Angiografía , Animales , Vasos Sanguíneos/patología , Estudios Transversales , Humanos , Imagenología Tridimensional , Verde de Indocianina , Microscopía Acústica/métodos , Imagen Multimodal/métodos , Placa Aterosclerótica/diagnóstico por imagen , Porcinos , Ultrasonografía/métodos
15.
Sci Rep ; 6: 35176, 2016 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-27731390

RESUMEN

Since its first implementation in otolaryngological surgery nearly a century ago, the surgical microscope has improved the accuracy and the safety of microsurgeries. However, the microscope shows only a magnified surface view of the surgical region. To overcome this limitation, either optical coherence tomography (OCT) or photoacoustic microscopy (PAM) has been independently combined with conventional surgical microscope. Herein, we present a near-infrared virtual intraoperative photoacoustic optical coherence tomography (NIR-VISPAOCT) system that combines both PAM and OCT with a conventional surgical microscope. Using optical scattering and absorption, the NIR-VISPAOCT system simultaneously provides surgeons with real-time comprehensive biological information such as tumor margins, tissue structure, and a magnified view of the region of interest. Moreover, by utilizing a miniaturized beam projector, it can back-project 2D cross-sectional PAM and OCT images onto the microscopic view plane. In this way, both microscopic and cross-sectional PAM and OCT images are concurrently displayed on the ocular lens of the microscope. To verify the usability of the NIR-VISPAOCT system, we demonstrate simulated surgeries, including in vivo image-guided melanoma resection surgery and in vivo needle injection of carbon particles into a mouse thigh. The proposed NIR-VISPAOCT system has potential applications in neurosurgery, ophthalmological surgery, and other microsurgeries.


Asunto(s)
Microscopía Acústica/métodos , Técnicas Fotoacústicas/métodos , Cirugía Asistida por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Animales , Simulación por Computador , Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Diseño de Equipo , Rayos Infrarrojos , Melanoma Experimental/diagnóstico por imagen , Melanoma Experimental/cirugía , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Microscopía Acústica/instrumentación , Microcirugia/instrumentación , Microcirugia/métodos , Técnicas Fotoacústicas/instrumentación , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/cirugía , Cirugía Asistida por Computador/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Interfaz Usuario-Computador
16.
Adv Exp Med Biol ; 923: 393-399, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27526168

RESUMEN

The function of the brain neural circuit is highly dependent on oxygen supply. Imaging the precise oxygen distribution and dynamics are critical for understanding the relationship between neuronal activity and oxygen dynamics of the nearby capillaries. Here, we develop fast acousto-optic scanning two-photon microscopy. Combined with oxygen probes, such as PtP-C343, we can monitor oxygen dynamics at the submicron level by this real-time microscopy. In this fast acousto-optic scanning microscopy, an acousto-optic deflector (AOD), an inertia-less scanner, is used to scan the femtosecond laser. A cylindrical lens is used to compensate the 'cylindrical lens effect' of AOD and a prism is used to compensate the chromatic dispersion of AOD. An electro-optical modulator (EOM) and a sCMOS camera are gated to measure the phosphorescence lifetime. With a 40× water objective lens, this set-up can image a 100 µm × 100 µm field of view at a speed of 20 frames per second and a 25 µm × 8 µm field of view at a speed of 500 frames per second. This real-time two-photon microscopy is expected to be a good tool for observing and recording the precise rapid oxygen dynamics in the cerebral cortex, which will facilitate studies of oxygen metabolism in neurosciences.


Asunto(s)
Corteza Cerebral/irrigación sanguínea , Corteza Cerebral/metabolismo , Circulación Cerebrovascular , Rayos Láser , Lentes , Microscopía Acústica/instrumentación , Microscopía de Fluorescencia por Excitación Multifotónica/instrumentación , Óptica y Fotónica/instrumentación , Consumo de Oxígeno , Oxígeno/sangre , Animales , Biomarcadores/sangre , Diseño de Equipo , Colorantes Fluorescentes/metabolismo , Cinética , Ratones
17.
J Biomed Opt ; 21(3): 36010, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27020602

RESUMEN

We propose an improved version of a synthetic aperture focusing technique (SAFT) based on a delay-multiply-and-sum algorithm for acoustic-resolution photoacoustic microscopy (AR-PAM). In this method, the photoacoustic (PA) signals from multiple scan-lines are combinatorially coupled, multiplied, and then summed. This process can be considered a correlation operation of the PA signals in each scan-line, so the spatial coherent information between the PA signals can be efficiently extracted. By applying this method in conventional AR-PAM, lateral resolution and signal-to-noise ratio in out-of-focus regions are much improved compared with those estimated from the previously developed SAFT, respectively, thereby achieving the extension of the imaging focal region. Our phantom and in vivo imaging experiments prove the validity of our proposed method.


Asunto(s)
Microscopía Acústica/métodos , Técnicas Fotoacústicas/métodos , Procesamiento de Señales Asistido por Computador , Abdomen/diagnóstico por imagen , Algoritmos , Animales , Diseño de Equipo , Miembro Posterior/diagnóstico por imagen , Ratones , Microscopía Acústica/instrumentación , Técnicas Fotoacústicas/instrumentación
18.
J Acoust Soc Am ; 139(1): 512-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26827044

RESUMEN

In this study, the speed of sound (SOS) of two types of rat livers (eight normal livers, four cirrhotic livers) was measured with a scanning acoustic microscope using two transducers, one of which had an 80-MHz and the other a 250-MHz center frequency. The 250-MHz transducer had a better spatial resolution adapted to studying fiber or hepatic parenchymal cells. In normal livers, averages of the SOS values were from 1598 to 1677 m/s at 80-MHz and from 1568 to 1668 m/s at 250-MHz. In the fiber tissue of cirrhotic livers, averages of the SOS values were from 1645 to 1658 m/s at 80-MHz and from 1610 to 1695 m/s at 250-MHz, while the SOS values in the other tissue of cirrhotic livers ranged from 1644 to 1709 m/s at 80-MHz and from 1641 to 1715 m/s at 250-MHz. In one liver, SOS in fiber tissue was larger than that of tissues without fiber while in others it was lower. The resulting two-dimensional SOS maps provide a unique quantitative insight of liver acoustic microstructures in a healthy liver and in a cirrhotic ones. This study would be helpful to understand the complex relationship between acoustic properties and liver disease including fiber tissue.


Asunto(s)
Cirrosis Hepática/fisiopatología , Hígado/fisiopatología , Sonido , Animales , Diseño de Equipo , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Masculino , Microscopía Acústica/instrumentación , Microscopía Acústica/métodos , Ratas , Espectrografía del Sonido
19.
Ann Biomed Eng ; 44(3): 649-66, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26471785

RESUMEN

At the intersection of life sciences, materials science, engineering, and medicine, regenerative medicine stands out as a rapidly progressing field that aims at retaining, restoring, or augmenting tissue/organ functions to promote the human welfare. While the field has witnessed tremendous advancements over the past few decades, it still faces many challenges. For example, it has been difficult to visualize, monitor, and assess the functions of the engineered tissue/organ constructs, particularly when three-dimensional scaffolds are involved. Conventional approaches based on histology are invasive and therefore only convey end-point assays. The development of volumetric imaging techniques such as confocal and ultrasonic imaging has enabled direct observation of intact constructs without the need of sectioning. However, the capability of these techniques is often limited in terms of penetration depth and contrast. In comparison, the recently developed photoacoustic microscopy (PAM) has allowed us to address these issues by integrating optical and ultrasonic imaging to greatly reduce the effect of tissue scattering of photons with one-way ultrasound detection while retaining the high optical absorption contrast. PAM has been successfully applied to a number of studies, such as observation of cell distribution, monitoring of vascularization, and interrogation of biomaterial degradation. In this review article, we highlight recent progress in non-invasive and volumetric characterization of biomaterial-tissue interactions using PAM. We also discuss challenges ahead and envision future directions.


Asunto(s)
Materiales Biocompatibles , Microscopía Acústica/instrumentación , Microscopía Acústica/métodos , Animales , Humanos
20.
J Biomed Opt ; 20(11): 116002, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26524679

RESUMEN

The short focal depth of a Gaussian beam limits the volumetric imaging speed of optical resolution photoacoustic microscopy (OR-PAM). A Bessel beam, which is diffraction free, provides a long focal depth, but its side lobes deteriorate image quality when the Bessel beam is directly employed to excite photoacoustic (PA) signals in OR-PAM. We present a nonlinear approach based on the Grueneisen relaxation effect to suppress the side-lobe artifacts in PA imaging. This method extends the focal depth of OR-PAM and speeds up volumetric imaging. We experimentally demonstrated a 1-mm focal depth with a 7-µm lateral resolution and volumetrically imaged a carbon fiber and red blood cell samples.


Asunto(s)
Eritrocitos/citología , Aumento de la Imagen/instrumentación , Imagenología Tridimensional/instrumentación , Microscopía Acústica/instrumentación , Técnicas Fotoacústicas/instrumentación , Células Cultivadas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...